Tag

Tag

URL

http://<<ip address>>/rest/controller/«controllerno»/tag/«tagid»

Method

GET

Description

Receives information of a tag.

controllerno is a number, tagid is an PTL ident (in the case of ATOP, this is also a number).

For the standardised PTL cabinet, controller 1 is the front, controller 2 is the back. Tag IDs are numbered from 11 upwards (left-to-right, bottom-to-top).

Response

{ "value": «lastdisplayedvalue», "state": «state» }

Possible Error

HTTP404 with no body when controller does not exist

Note when the cabinet sides setting is set to frontonly, controller 2 will not be available and this will result in an HTTP404.

URL

http://<<ip address>>/rest/controller/«controllerno»/tag/«tagid»

Method

PUT

Description

Sets value and color on a tag.

controllerno is a number, tagid is an PTL ident (in the case of ATOP, this is also a number).

For the standardised PTL cabinet, controller 1 is the front, controller 2 is the back. Tag IDs are numbered from 11 upwards (left-to-right, bottom-to-top).

Request

{ "value": «valuetodisplay», ["color": "red|green|orange|blue|pink|cyan|none"], ["blinking": "on|off|blink2sec|blink1sec|blink05sec|blink025sec"] }

value should be a string, if value is null, the tag is switched off.

color is optional. When no color is chosen, it defaults to red.

blinking should be a string, it defaults to on(i.e. no blinking). off causes the LED to switch off (identical to "color": "none")

Response

HTTP204 when successful

Possible Errors

HTTP400 when request was invalid

{ "message": «human readable error» }

HTTP404 with no body when controller does not exist

Note when the cabinet sides setting is set to frontonly, controller 2 will not be available and this will result in an HTTP404.

Remarks

v2.2:

  • Blinking support added.

URL

http://<<ip address>>/rest/controller/«controllerno»/tag/

Method

PUT

Description

Sets value and color on a range of tags.

controllerno is a number

For the standardised PTL cabinet, controller 1 is the front, controller 2 is the back. Tag IDs are numbered from 11 upwards (left-to-right, bottom-to-top).

Request

value should be a string, when set to null the tag is switched off (v2.1.2+).

color is optional. When no color is chosen, it defaults to red.

blinking should be a string, it defaults to on(i.e. no blinking). off causes the LED to switch off (identical to "color": "none")

Response

HTTP204 when successful

Possible Errors

HTTP400 when request was invalid

HTTP404 with no body when controller does not exist

HTTP409 when cabinet not in correct mode

Note when the cabinet sides setting is set to frontonly, controller 2 will not be available and this will result in an HTTP404.

Remarks

v2.2:

  • Blinking support added.

v2.1.2:

  • Tags are no longer switched off before setting the tag range. (You can handle the switching off of tags by yourself, using the cabinet/lightest call. When used with off, this switches off all lights).

v2.1.1:

  • All tags are switched off before the range is set, this means sending [] causes all tags to be switched off.

v2.1:

  • Tag range call added

Related content